{"id":284,"date":"2026-11-16T21:19:58","date_gmt":"2026-11-17T04:19:58","guid":{"rendered":"https:\/\/fourpointfire.com\/blog\/sprinkler-pipe-corrosion\/"},"modified":"2026-11-16T21:20:03","modified_gmt":"2026-11-17T04:20:03","slug":"sprinkler-pipe-corrosion","status":"publish","type":"post","link":"https:\/\/fourpointfire.com\/blog\/sprinkler-pipe-corrosion\/","title":{"rendered":"Sprinkler Pipe Corrosion: Causes, Warning Signs and Freeze Risks"},"content":{"rendered":"<\/p>\n<p>Sprinkler pipe corrosion is caused mainly by water and oxygen working together inside steel piping. It stays hidden for years, so the practical answer is a scheduled internal assessment, a response plan for the warning signs, and freeze protection before winter. Our team at FourPoint Fire &amp; Water provides inspection, installation, maintenance, design and consulting for sprinkler systems, fire hydrants, standpipes, backflow prevention, cross-connection control and related underground piping in Grande Prairie, Dawson Creek and the Peace Region. This guide covers what property managers and facility operators need to know about corrosion and freezing in sprinkler systems.<\/p>\n<div data-blg-cta=\"after_tldr\" data-blg-cta-layout=\"split\" style=\"margin:28px 0;font-family:-apple-system, BlinkMacSystemFont, &apos;Segoe UI&apos;, Roboto, Helvetica, Arial, sans-serif\">\n<div style=\"border-radius:26px;padding:min(22px,3.2vw);background:radial-gradient(circle at 100% 0%,#f2d9d8 0 150px,rgba(255,255,255,0) 151px),radial-gradient(circle at 0% 100%,#f2d9d8 0 130px,rgba(255,255,255,0) 131px),linear-gradient(180deg,#f6e6e5 0%,#fbf2f2 100%)\">\n<div style=\"background:#ffffff;border-radius:18px;overflow:hidden\">\n<div style=\"display:flex;flex-wrap:wrap\">\n<div style=\"flex:1 0 36%;min-width:220px;padding:30px 76px 30px 26px;color:#ffffff;background:linear-gradient(104deg,#641916 0%,#3f100e 82%,rgba(0,0,0,0) 82.15%)\">\n<div style=\"margin:0 0 14px\"><span style=\"display:inline-block;max-width:100%;border-radius:999px;padding:6px 13px;font-size:12px;font-weight:800;letter-spacing:0.1em;text-transform:uppercase;line-height:1.3;background:#ffffff;color:#7a1f1b\">Fourpointfire<\/span><\/div>\n<div style=\"font-size:12px;opacity:0.75\">fourpointfire.com<\/div>\n<\/div>\n<div style=\"flex:999 1 300px;min-width:0;padding:30px 28px\">\n<div style=\"font-size:23px;font-weight:800;line-height:1.2;letter-spacing:-0.01em;color:#1f2937;margin:0\">Assess Corrosion Before It Spreads<\/div>\n<div style=\"width:56px;height:6px;border-radius:3px;background:#B82E29;margin:12px 0 14px\"><\/div>\n<div style=\"font-size:15px;line-height:1.55;color:#64748b;margin:0 0 22px\">FourPoint evaluates fire safety systems in their operating context, helping property managers understand corrosion concerns and make informed decisions.<\/div>\n<p><a href=\"https:\/\/fourpointfire.com\/\" style=\"display:inline-flex;align-items:center;gap:9px;border-radius:10px;font-weight:700;font-size:15px;text-decoration:none;padding:13px 22px 13px 26px;background:#B82E29;color:#ffffff\">Visit<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2 id=\"tldr\" tabindex=\"-1\">TL;DR<\/h2>\n<ul>\n<li>Corrosion in steel sprinkler pipe comes from water plus oxygen. Dry systems with trapped water and wet systems with trapped air are the most exposed.<\/li>\n<li>Brown or black drain water, pinhole leaks, scale on heads and falling flow are the signs that call for an internal pipe investigation.<\/li>\n<li>Internal corrosion is hard to see during annual inspections, which is why NFPA 25 requires a formal internal assessment, generally every five years.<\/li>\n<li>Freezing can leave a building without fire protection and cause water damage. Keep piping areas above 4\u00b0C and confirm freeze protection before winter.<\/li>\n<li>Contact us to confirm availability for your location and to arrange a site-specific assessment.<\/li>\n<\/ul>\n<h2 id=\"table-of-contents\" tabindex=\"-1\">Table of Contents<\/h2>\n<ul>\n<li><a href=\"#what-causes-corrosion-inside-sprinkler-pipe\">What causes corrosion inside sprinkler pipe<\/a><\/li>\n<li><a href=\"#warning-signs-worth-acting-on\">Warning signs worth acting on<\/a><\/li>\n<li><a href=\"#what-corrosion-does-to-system-reliability\">What corrosion does to system reliability<\/a><\/li>\n<li><a href=\"#freezing-and-fire-protection-systems\">Freezing and fire protection systems<\/a><\/li>\n<li><a href=\"#what-the-code-asks-for-in-alberta\">What the code asks for in Alberta<\/a><\/li>\n<li><a href=\"#what-happens-when-corrosion-is-found\">What happens when corrosion is found<\/a><\/li>\n<li><a href=\"#who-does-what-and-where-we-fit\">Who does what, and where we fit<\/a><\/li>\n<li><a href=\"#perspective\">Perspective<\/a><\/li>\n<li><a href=\"#fire-protection-support-in-the-peace-region\">Fire protection support in the Peace Region<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<li><a href=\"#sources\">Sources<\/a><\/li>\n<\/ul>\n<h2 id=\"what-causes-corrosion-inside-sprinkler-pipe\" tabindex=\"-1\">What causes corrosion inside sprinkler pipe<\/h2>\n<p>FM Global\u2019s research on corrosion in fire protection systems lists several contributors: <a href=\"https:\/\/www.fm.com\/-\/media\/project\/publicwebsites\/fm\/files\/resources\/research-technical-reports\/p14180.pdf\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">pipe weld corrosion, residual water in dry systems, trapped air in wet systems, corrosive water chemistry, repeated fresh oxygenated water, stagnant water and microbiologically influenced corrosion<\/a>. The same report identifies dissolved oxygen in the water as the major factor driving corrosion in steel sprinkler piping.<\/p>\n<p>FM Global\u2019s guidance on sprinkler corrosion puts it simply: <a href=\"https:\/\/www.fm.com\/FMAApi\/data\/ApprovalStandardsDownload?isGated=false&amp;itemId=%7B2FBD372E-72FE-4945-938D-179D0150CE2A%7D\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">steel rusts where water and oxygen are present, and in dry systems that use compressed air, any water left in the pipe causes rapid corrosion<\/a>.<\/p>\n<p>In practical terms:<\/p>\n<ul>\n<li><strong>Dry pipe and pre-action systems<\/strong> hold compressed air instead of water. Water pools at low points from condensation or after a trip test, and it sits against the pipe wall. <a href=\"https:\/\/blog.qrfs.com\/215-my-fire-sprinkler-pipes-are-corroded-now-what\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Dry systems are generally considered the most at risk<\/a> for this reason.<\/li>\n<li><strong>Wet pipe systems<\/strong> corrode where air is trapped at high points, and every time the system is drained and refilled with fresh, oxygenated water.<\/li>\n<li><strong>Microbiologically influenced corrosion (MIC)<\/strong> is corrosion driven by bacteria living in stagnant water. It is typically linked to black water and sulfur odour.<\/li>\n<\/ul>\n<h2 id=\"warning-signs-worth-acting-on\" tabindex=\"-1\">Warning signs worth acting on<\/h2>\n<p>Corrosion usually begins on the inside. NFPA\u2019s technical services engineer notes that <a href=\"https:\/\/www.nfpa.org\/news-blogs-and-articles\/blogs\/2020\/08\/28\/corrosion-in-sprinkler-systems\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">internal corrosion is harder to identify during annual inspections<\/a>, so visible effects such as water stains and pinhole leaks should be watched for between assessments.<\/p>\n<p>Signs that a facility team can spot during routine rounds include:<\/p>\n<ul>\n<li>Orange-brown rust or dark slime around fittings, heads and low-point drains, and <a href=\"https:\/\/www.ecscorrosion.com\/blog\/fire-sprinkler-corrosion-warning-signs-and-prevention-tips\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">unexplained stains or drips from pinhole leaks<\/a><\/li>\n<li>Brown or black water when draining or testing the system<\/li>\n<li>Frequent air compressor cycling on a dry system, which can point to leaks<\/li>\n<li>Reduced flow or pressure, and repeated leak repairs in the same area<\/li>\n<li>Corroded or heavily scaled sprinkler heads<\/li>\n<\/ul>\n<p>One published guide reads <a href=\"https:\/\/ca-fire.com\/fire-sprinkler-corrosion-prevention-mic\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">orange-brown drain water as active iron-oxide corrosion and black water as a possible sign of MIC<\/a>. The same guide treats a residual pressure drop of more than 10% on the annual main drain test, compared with the prior year, as a sign of internal obstruction. Treat these as triggers to investigate, not as a diagnosis. Only an internal examination shows what is inside the pipe.<\/p>\n<h3 id=\"black-water-in-a-sprinkler-system\" tabindex=\"-1\">Black water in a sprinkler system<\/h3>\n<p>Black water on a main drain or inspector\u2019s test is a common question. It can mean MIC, but it can also come from dissolved iron and sediment disturbed during the test. Record when and where you saw it, keep the record with your inspection reports, and have the pipe assessed.<\/p>\n<h2 id=\"what-corrosion-does-to-system-reliability\" tabindex=\"-1\">What corrosion does to system reliability<\/h2>\n<p>The NFPA explains that corrosion can cause <a href=\"https:\/\/www.nfpa.org\/news-blogs-and-articles\/blogs\/2020\/08\/28\/corrosion-in-sprinkler-systems\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">pinhole leaks, rust buildup that limits flow, clogged sprinkler orifices, damaged deflectors, and plugs that seal shut so water never reaches a fire<\/a>. Hangers and fittings are also susceptible. The risk is two-sided: a leak damages the building, and an obstruction reduces the protection the system was designed to deliver. Our related piece on <a href=\"https:\/\/www.fourpointfire.com\/blog\/sprinkler-water-damage\" target=\"_blank\" rel=\"noopener\">sprinkler water damage causes and prevention<\/a> covers the leak side in more detail.<\/p>\n<h2 id=\"freezing-and-fire-protection-systems\" tabindex=\"-1\">Freezing and fire protection systems<\/h2>\n<p>Freezing is a particular concern across the Peace Region. FM Global\u2019s loss prevention guidance warns that cold weather brings <a href=\"https:\/\/www.scribd.com\/document\/518831647\/FMDS0281\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">impaired fire protection from water freezing in equipment, extended repair times, and water leakage from ruptured components<\/a>. It recommends an active cold-weather readiness program.<\/p>\n<p>A freeze-up has two consequences: a split pipe or fitting floods the space once it thaws, and the system may be out of service while it is repaired. Practical steps from an insurer\u2019s guidance for Canadian properties:<\/p>\n<ul>\n<li>Keep indoor temperatures, including valve rooms, fire pump rooms and vacant areas, <a href=\"https:\/\/ecclesiastical.ca\/wp-content\/uploads\/EIO_BG_WP_SprinklerSystem_02-2023.pdf\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">above 4\u00b0C (40\u00b0F)<\/a><\/li>\n<li>Check temperature gauges daily, and more often in severe cold<\/li>\n<li>Inspect visible sprinkler parts regularly in extreme cold and seal drafts<\/li>\n<li>Post the emergency contacts of your maintenance provider where staff can find them<\/li>\n<\/ul>\n<p>Where heat tracing is used on sprinkler or standpipe piping, requirements are specific. The City of Surrey, for example, says <a href=\"https:\/\/www.surrey.ca\/sites\/default\/files\/media\/documents\/FreezeProtectionOfPiping.pdf\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">heat-trace cable must be specifically approved, hold piping at 4\u00b0C minimum, be installed by a registered electrical contractor under permit, and be monitored through the fire alarm system<\/a>. That is a British Columbia municipal rule, so confirm what your own authority having jurisdiction (AHJ), the local body that enforces the fire code, requires.<\/p>\n<p>A frozen outdoor hydrant is the same problem in a different place. If winter failures on private or municipal hydrants are a concern, see our <a href=\"https:\/\/www.fourpointfire.com\/hydrant-troubleshooting.html\" target=\"_blank\" rel=\"noopener\">hydrant troubleshooting<\/a> and <a href=\"https:\/\/www.fourpointfire.com\/hydrant-maintenance.html\" target=\"_blank\" rel=\"noopener\">hydrant maintenance<\/a> pages.<\/p>\n<h2 id=\"what-the-code-asks-for-in-alberta\" tabindex=\"-1\">What the code asks for in Alberta<\/h2>\n<p>NFPA 25 is the standard for inspection, testing and maintenance of water-based fire protection systems. According to a Canadian inspection firm, <a href=\"https:\/\/www.rssterling.ca\/resources\/blog\/five-year-internal-sprinkler-inspection\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">in Alberta the edition that counts is NFPA 25-2017, because the National Fire Code 2023 Alberta Edition points to that standard<\/a>, unless the AHJ or your contract says otherwise. The five-year internal inspection is a look inside the pipe to see whether rust, scale, sediment or other material has built up enough to block water.<\/p>\n<p>A summary of NFPA 25 Chapter 14 describes <a href=\"https:\/\/ca-fire.com\/fire-sprinkler-corrosion-prevention-mic\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">internal pipe inspection every 3 years for dry pipe and pre-action systems and every 5 years for wet pipe systems<\/a>. Confirm the interval and the edition applied to your building with your AHJ and in your inspection contract. Our <a href=\"https:\/\/www.fourpointfire.com\/standards-guidance.html\" target=\"_blank\" rel=\"noopener\">standards and scope page<\/a> explains how we frame these references.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/fourpointfire.com\/blog\/wp-content\/uploads\/2026\/11\/1794889194058_What-the-code-asks-for-in-Alberta.jpeg\" alt=\"What the code asks for in Alberta\"><\/p>\n<h2 id=\"what-happens-when-corrosion-is-found\" tabindex=\"-1\">What happens when corrosion is found<\/h2>\n<p>FM Global\u2019s guidance for systems with pinhole leaks, scale or tubercles (mounds of corrosion product on the pipe wall) sets out a clear sequence: <a href=\"https:\/\/www.fm.com\/FMAApi\/data\/ApprovalStandardsDownload?isGated=false&amp;itemId=%7B2FBD372E-72FE-4945-938D-179D0150CE2A%7D\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">check for obstructed waterways, inspect pipe with a video borescope, flush if obstructions are found, replace sections that cannot be cleared, and have a sample examined metallurgically<\/a>.<\/p>\n<p>The same data sheet recommends measures at installation or renewal: Schedule 40 pipe in leak-sensitive occupancies, no internally galvanized pipe in wet systems, and automatic air-release valves at high points to remove trapped air. Another FM data sheet cautions that <a href=\"https:\/\/www.scribd.com\/document\/518831647\/FMDS0281\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">chemical cleaners and inhibitors are generally discouraged<\/a> because treatment concentration can vary across dead ends.<\/p>\n<p>A typical decision path looks like this:<\/p>\n<table>\n<thead>\n<tr>\n<th>Finding<\/th>\n<th>Typical response<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Light surface scale, no pitting<\/td>\n<td>Flush and monitor<\/td>\n<\/tr>\n<tr>\n<td>Shallow pitting, limited wall loss<\/td>\n<td>Flush, treat, re-inspect and plan for replacement<\/td>\n<\/tr>\n<tr>\n<td>Active MIC, deep pitting or recurring leaks<\/td>\n<td>Replace the affected zone<\/td>\n<\/tr>\n<tr>\n<td>Older system with widespread pitting<\/td>\n<td>Consider full replacement<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>This table follows <a href=\"https:\/\/ca-fire.com\/fire-sprinkler-corrosion-prevention-mic\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">one published repair decision guide<\/a>. The right action for your building depends on measured wall loss and the findings of the assessment.<\/p>\n<p>While a system is impaired during repairs, many properties arrange interim protection. A <a href=\"https:\/\/trustpointsecurity.ca\/fire-watch-security\" target=\"_blank\" rel=\"noopener\">fire watch service<\/a> provides trained personnel who patrol the building until the system is back in service. Check with your AHJ and insurer on what they require.<\/p>\n<h2 id=\"who-does-what-and-where-we-fit\" tabindex=\"-1\">Who does what, and where we fit<\/h2>\n<p>A site-specific assessment starts with the equipment, its age, the water supply and how the building operates. Our process emphasizes clear communication, so scope, context and equipment details are settled before any work is arranged. For sprinkler systems that means <a href=\"https:\/\/www.fourpointfire.com\/sprinkler-inspections.html\" target=\"_blank\" rel=\"noopener\">sprinkler inspections<\/a> and <a href=\"https:\/\/www.fourpointfire.com\/sprinkler-repairs.html\" target=\"_blank\" rel=\"noopener\">sprinkler repairs<\/a>. Where corrosion extends to buried piping or hydrants, our work covers related underground piping and fire hydrants as well.<\/p>\n<h2 id=\"perspective\" tabindex=\"-1\">Perspective<\/h2>\n<blockquote>\n<p>Most corrosion problems we hear about start the same way: a system that passed a visual walk-through for years while the inside of the pipe changed. Our approach is to look at the operating context first: what kind of system it is, how the water is supplied, how the building is heated and how the system has been drained and refilled.<\/p>\n<p>Because hydrants, sprinklers, standpipes, backflow assemblies and underground piping share the same water, we prefer to look at them together. A corroded hydrant barrel and a corroded sprinkler riser are often two symptoms of the same supply conditions.<\/p>\n<p>Plan the winter before it arrives. Freeze protection is cheaper to check in October than to repair in January.<\/p>\n<p><em>Kevin<\/em><\/p>\n<\/blockquote>\n<h2 id=\"fire-protection-support-in-the-peace-region\" tabindex=\"-1\">Fire protection support in the Peace Region<\/h2>\n<p>FourPoint is led by Kevin Ballantyne, a Red Seal Journeyman Sprinkler Fitter who entered the trade in 2001 and earned his journeyman ticket in 2014. Our services include inspection, installation, maintenance, design and consulting for fire hydrants, sprinkler systems, standpipes, backflow prevention, cross-connection control and related underground piping. We offer 24 hour emergency response for locations within 200 km. Please contact us to confirm availability for your location.<\/p>\n<p>For hydrants, which are a large part of our work, see our <a href=\"https:\/\/www.fourpointfire.com\/hydrants.html\" target=\"_blank\" rel=\"noopener\">fire hydrant services<\/a>, including inspection, preventative maintenance, repair, replacement and winter-related failures.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/fourpointfire.com\/blog\/wp-content\/uploads\/2026\/11\/1794453426692_fourpointfire.jpg\" alt=\"Fourpointfire\"><\/p>\n<p>For an overview of everything we cover, see our <a href=\"https:\/\/www.fourpointfire.com\/services.html\" target=\"_blank\" rel=\"noopener\">fire protection guide<\/a>.<\/p>\n<h2 id=\"faq\" tabindex=\"-1\">FAQ<\/h2>\n<h3 id=\"how-often-should-sprinkler-pipe-be-inspected-internally\" tabindex=\"-1\">How often should sprinkler pipe be inspected internally?<\/h3>\n<p>NFPA 25 calls for an internal assessment of piping. A published summary of Chapter 14 gives every 5 years for wet systems and every 3 years for dry and pre-action systems. Confirm the interval and edition with your AHJ and your inspection contract.<\/p>\n<h3 id=\"why-is-the-water-from-my-sprinkler-drain-black\" tabindex=\"-1\">Why is the water from my sprinkler drain black?<\/h3>\n<p>Black water can indicate microbiologically influenced corrosion, which is often accompanied by a sulfur smell. It can also reflect sediment stirred up during the test. Document it and arrange an internal pipe assessment to find out which.<\/p>\n<h3 id=\"can-a-sprinkler-system-freeze\" tabindex=\"-1\">Can a sprinkler system freeze?<\/h3>\n<p>Yes. Water in pipes, valves and fittings exposed to cold can freeze, which may split components and leave the system impaired. Keeping piping areas above 4\u00b0C and confirming freeze protection before winter reduces that risk.<\/p>\n<h3 id=\"what-should-i-do-if-i-find-pinhole-leaks\" tabindex=\"-1\">What should I do if I find pinhole leaks?<\/h3>\n<p>Pinhole leaks are a recognized trigger for checking the system for obstructed waterways and for examining the pipe. Contact a qualified sprinkler contractor, such as our team, to assess the system before the leaks spread.<\/p>\n<div data-blg-cta=\"article_end\" data-blg-cta-layout=\"contact_line\" style=\"margin:28px 0;font-family:-apple-system, BlinkMacSystemFont, &apos;Segoe UI&apos;, Roboto, Helvetica, Arial, sans-serif\">\n<div style=\"border-radius:26px;padding:min(22px,3.2vw);background:radial-gradient(circle at 100% 0%,#f2d9d8 0 150px,rgba(255,255,255,0) 151px),radial-gradient(circle at 0% 100%,#f2d9d8 0 130px,rgba(255,255,255,0) 131px),linear-gradient(180deg,#f6e6e5 0%,#fbf2f2 100%)\">\n<div style=\"background:#ffffff;border-radius:18px;overflow:hidden\">\n<div style=\"padding:min(30px,6vw) min(32px,4.5vw) min(28px,6vw)\">\n<div style=\"margin:0 0 16px\"><span style=\"display:inline-block;max-width:100%;border-radius:999px;padding:6px 13px;font-size:12px;font-weight:800;letter-spacing:0.1em;text-transform:uppercase;line-height:1.3;background:#B82E29;color:#ffffff\">Fourpointfire<\/span><\/div>\n<div style=\"font-size:22px;font-weight:800;line-height:1.15;letter-spacing:-0.02em;color:#1f2937;margin:0\">Discuss Sprinkler Pipe Concerns<\/div>\n<div style=\"font-size:15px;line-height:1.6;color:#64748b;margin:10px 0 0;max-width:46em\">Reach out to discuss your sprinkler system concerns and FourPoint\u2019s inspection, maintenance, and repair services in the Peace Region.<\/div>\n<div style=\"height:1px;margin:22px 0 20px\"><\/div>\n<div style=\"display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:14px 24px\"><a href=\"tel:+15872972336\" style=\"text-decoration:none;display:block;flex:1 1 auto;min-width:0\"><span style=\"display:block;font-size:27px;font-weight:800;line-height:1.1;letter-spacing:-0.02em;color:#1f2937\"><span style=\"display:block;min-width:0;white-space:nowrap;overflow:hidden\">+1 587 297 2336<\/span><\/span><\/a><a href=\"tel:+15872972336\" style=\"text-decoration:none;display:inline-flex;align-items:center;gap:10px;border-radius:999px;padding:13px 22px 13px 16px;font-size:15px;font-weight:700;white-space:nowrap;max-width:100%;background:linear-gradient(180deg,#bf433e,#B82E29);color:#ffffff\"><span style=\"min-width:0;overflow:hidden\">Call FourPoint<\/span><\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2 id=\"sources\" tabindex=\"-1\">Sources<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.fm.com\/-\/media\/project\/publicwebsites\/fm\/files\/resources\/research-technical-reports\/p14180.pdf\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">FM Global research report on corrosion in fire protection systems<\/a><\/li>\n<li><a href=\"https:\/\/www.fm.com\/FMAApi\/data\/ApprovalStandardsDownload?isGated=false&amp;itemId=%7B2FBD372E-72FE-4945-938D-179D0150CE2A%7D\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">FM Global Data Sheet 2-1, Corrosion in Automatic Sprinkler Systems<\/a><\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/news-blogs-and-articles\/blogs\/2020\/08\/28\/corrosion-in-sprinkler-systems\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">NFPA: Sprinkler System Corrosion and Steps to Help Minimize It<\/a><\/li>\n<li><a href=\"https:\/\/www.ecscorrosion.com\/blog\/fire-sprinkler-corrosion-warning-signs-and-prevention-tips\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Engineered Corrosion Solutions: warning signs and prevention<\/a><\/li>\n<li><a href=\"https:\/\/ca-fire.com\/fire-sprinkler-corrosion-prevention-mic\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Fire sprinkler corrosion, causes, prevention and MIC guide<\/a><\/li>\n<li><a href=\"https:\/\/blog.qrfs.com\/215-my-fire-sprinkler-pipes-are-corroded-now-what\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Fire sprinkler corrosion: prevention and fixing<\/a><\/li>\n<li><a href=\"https:\/\/www.scribd.com\/document\/518831647\/FMDS0281\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">FM Global Data Sheet 2-81 (ITM)<\/a><\/li>\n<li><a href=\"https:\/\/ecclesiastical.ca\/wp-content\/uploads\/EIO_BG_WP_SprinklerSystem_02-2023.pdf\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Ecclesiastical: avoiding freeze-ups and malfunctions<\/a><\/li>\n<li><a href=\"https:\/\/www.surrey.ca\/sites\/default\/files\/media\/documents\/FreezeProtectionOfPiping.pdf\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">City of Surrey: freeze protection of standpipes<\/a><\/li>\n<li><a href=\"https:\/\/www.rssterling.ca\/resources\/blog\/five-year-internal-sprinkler-inspection\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Five-year internal sprinkler inspection in Alberta<\/a><\/li>\n<\/ul>\n<h2 id=\"recommended\" tabindex=\"-1\">Recommended<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.fourpointfire.com\/blog\/sprinkler-water-damage\" target=\"_blank\" rel=\"noopener\">Sprinkler Water Damage: Causes &amp; Prevention<\/a><\/li>\n<li><a href=\"https:\/\/www.fourpointfire.com\/blog\/backflow-preventer-leaks\" target=\"_blank\" rel=\"noopener\">Backflow Preventer Leaks: Causes &amp; First Steps<\/a><\/li>\n<li><a href=\"https:\/\/www.fourpointfire.com\/sprinkler-repairs.html\" target=\"_blank\" rel=\"noopener\">Sprinkler Repairs<\/a><\/li>\n<li><a href=\"https:\/\/www.fourpointfire.com\/sprinkler-inspections.html\" target=\"_blank\" rel=\"noopener\">Sprinkler Inspections<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>What corrodes sprinkler pipe, the signs to watch for, how freezing damages fire protection systems, and what NFPA 25 asks of property managers in Alberta.<\/p>\n","protected":false},"author":1,"featured_media":285,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"wpai_generated_summary":"","wpai_tts_display_audio":true,"wpai_meta_description":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-284","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/posts\/284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/comments?post=284"}],"version-history":[{"count":1,"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/posts\/284\/revisions"}],"predecessor-version":[{"id":287,"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/posts\/284\/revisions\/287"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/media\/285"}],"wp:attachment":[{"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/media?parent=284"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/categories?post=284"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fourpointfire.com\/blog\/wp-json\/wp\/v2\/tags?post=284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}